سریعترین رله حال حاظر برای حفاظت خطوط انتقال
SEL-T400L
این رله بر اساس زمان و امواج انتشاری نتیجه خطا عمل می کند. از زمان تشخیص خطا تا ارسال تریپ، این رله ده برابر به نسبت رله های معمولی سریعتر عمل میکند. این رله برای خطوط انتقال حساس پیشنهاد می شود.
Built for speed, security, and simplicity.
- • 1 ms traveling wave elements: TW87 and TW32.
- • 4 ms time-domain elements: TD21 and TD32.
- • Easy to set and less dependent on short-circuit studies.
- • Nearest-tower fault location, with and without communications.
- • Time-synchronized, high-resolution data recorder with 1 MHz
- • 18-bit sampling rate captures transient events.
- • Complements your traditional protection and gives you speed.
Key Features
Ultra-High-Speed Fault-Clearing Times With Security Protect critical lines using the SEL-T400L with timedomain principles. The relay operates at ultra-high speeds without compromising security. The incrementalquantity- based TD21 distance element can be set as far as 80 percent of the line length and operates in the order of 4 ms without communications. The POTT scheme with an incremental quantity-based TD32 directional element operates as fast as 2 ms, and the TW32 directionalelement operates as fast as 1 ms. The TW87 traveling-wavedifferential element operates in 1 to 4 ms, depending onthe line length and fault location. The relay includes solidstate, trip-rated outputs. When used with a low-latency communications channel, the SEL-T400L trips breakers in
the order of 4 to 6 ms for the vast majority of line faults.
Easy Settings and Deployment Use the SEL-T400L with existing control cables and wiring to connect to conventional current and voltage transformers, including CCVTs. The traveling wave differential (TW87) element uses current inputs for differential protection. The traveling wave directional (TW32) element can be used with CCVTs because it relies on stray capacitances for measuring the polarity of the first voltage wave. The incremental quantity elements (TD21 and TD32) use a lower-frequency spectrum and work well with any voltage or current transformer. Use
fast Mirrored Bits communications over direct fiber or a multiplexer for communications-assisted schemes. The TW87 differential element uses a dedicated 1 Gbps direct fiber channel for both communications and data alignment. None of the SEL-T400L protection elements require an absolute time input, such as IRIG-B. Setting the SEL-T400L is simple and does not require complex short-circuit studies. It uses nameplate data that do not need to be reevaluated as the system evolves.
These include current and voltage transformer ratios, line impedances and length, TD21 reach, and port configuration settings.