Testing and Commissioning of Protective Relays

Testing and Commissioning of Protective Relays

تست و راه اندازی رله های حفاظتی

مربی: دکتر سعید روستایی
ویدیوهای از پیش ضبط شده با دسترسی آنلاین + به روز رسانی رایگان + گواهینامه رایگان + پشتیبانی فنی رایگان

توضیحات

The testing & commissioning of the protection relays can be done by different testing software and hardware. In this training, we have used OMICRON Test universe, Vebko AMpro, and FREJA win.

pplementary Files: The important related files/ videos /software and attached them to the course as supplementary files.

Any queries, please feel free to contact us: saeed61850@gmail.com

Part A: Introduction, general settings, Hardware & connection, Impedance/Vector/report View, the test object, …

  • A 01 (Length: 02 min, uploaded: Oct 3, 2021): Introduction
  • A 02 (Length: 05 min, uploaded: Oct 3, 2021): Strat page (Omicron)
  • A 03 (Length: 06 min, uploaded: Oct 3, 2021): General settings (Omicron)
  • A 04 (Length: 05 min, uploaded: Oct 3, 2021): Strat page (Vebko)
  • A 05 (Length: 14 min, uploaded: Oct 3, 2021): Phasor view, Impedance view (Omicron)
  • A 06 (Length: 06 min, uploaded: Oct 3, 2021): Phasor view, Impedance view, differential veiw (Vebko)
  • A 07 (Length: 04 min, uploaded: Oct 3, 2021): Hardware connection
  • A 08 (Length: 10 min, uploaded: Oct 3, 2021): Practical section with Omciron 256 plus, SEL 421

Part B: Overcurrent and Directional Overcurrent Functions (67, 67N, 50, 51, 50N, 51N)

  • B 01 (Length: 19 min, uploaded: Oct 3, 2021): Test object, Overcurrent RIO block, testing of overcurrent
  • B 02 (Length: 16 min, uploaded: Oct 3, 2021): Settings of the Overcurrent test module
  • B 03 (Length: 15 min, uploaded: Oct 3, 2021): Practical section
  • B 04 (Length: 17 min, uploaded: Oct 3, 2021): Practical section
  • B 05 (Length: 06 min, uploaded: Oct 3, 2021): Practical section
  • B 06 (Length: 15 min, uploaded: Oct 3, 2021): Practical section
  • B 07 (Length: 09 min, uploaded: Oct 3, 2021): Practical section
  • B 08 (Length: 15 min, uploaded: Oct 3, 2021): Practical section
  • B 09 (Length: 22 min, uploaded: Oct 3, 2021): Practical section
  • B 10 (Length: 23 min, uploaded: Oct 3, 2021): Practical section (directional overcurrent conecpts, settings, practice)
  • B 11 (Length: 06 min, uploaded: Oct 3, 2021): Practical section (directional overcurrent testing)

Part C: Differential Protection Functions (87G, 87T, 87L)

  • C 01 (Length: 03 min, uploaded: Oct 27, 2021): Diff protection principal
  • C 02 (Length: 11 min, uploaded: Oct 27, 2021): Diff parameters
  • C 03 (Length: 12 min, uploaded: Oct 27, 2021): Diff RIO block
  • C 04 (Length: 05 min, uploaded: Oct 27, 2021): Diff configuration
  • C 05 (Length: 07 min, uploaded: Oct 27, 2021): Diff Operating Characteristic
  • C 06 (Length: 12 min, uploaded: Oct 27, 2021): Diff Trip Time Characteristic & Diff Harmonic Restraint

Part D: XRIO and PTL

  • D 01 (Length: 13 min, uploaded: Nov 13, 2021): RIO and XRIO history and why we should use this format for relay testing, RIO structure, XRIO structure, Differences between RIO and XRIO files, XRIO features & benefits, LinkToXRIO
  • D 02 (Length: 05 min, uploaded: Nov 13, 2021): XRIO template, How to Import Relay Settings, How to find a proper XRIO template and filter based on the relay
  • D 03 (Length: 08 min, uploaded: Nov 13, 2021): Common issues while loading the relay settings into a template and how to solve the issues, XRIO template based on the relay versions
  • D 04 (Length: 06 min, uploaded: Nov 13, 2021): Explain a case study XRIO file
  • D 05 (Length: 10 min, uploaded: Nov 13, 2021): Modify a case study XRIO file
  • D 06 (Length: 09 min, uploaded: Nov 13, 2021): Modify the XRIO template, RIO blocks

Part E: Impedance Protection Functions

  • E 01 (Length: 09 min, uploaded: Nov 26, 2021): Distance RIO block
  • E 02 (Length: 07 min, uploaded: Nov 26, 2021): Advance Distance Test Module settings
  • E 03 (Length: 08 min, uploaded: Nov 26, 2021): Distance protection function principal, Impedance View
  • E 04 (Length: 18 min, uploaded: Nov 26, 2021): Analysis of server faults visually in the impedance view
  • E 05 (Length: 19 min, uploaded: Nov 26, 2021): Analysis of several distance relays (RAZOA, ABB REL670, SEL421, Siemens 7SA8x, MiCOM P442, NR PCS 931S, Protecta)
  • E 06 (Length: 08 min, uploaded: Nov 26, 2021): Distance Test Module settings
  • E 07 (Length: 12 min, uploaded: Nov 26, 2021): Preparing XRIO file for testing of impedance protection functions

Part F: Autoreclosure Function (ANSI 79)

  • F 01 (Length: 04 min, uploaded: Dec 03, 2021): Autoreclosure Description, auto reclose process
  • F 02 (Length: 05 min, uploaded: Dec 03, 2021): Autoreclosure settings, Autoreclose timing diagram
  • F 03 (Length: 11 min, uploaded: Dec 03, 2021): Autoreclosure simulation
  • F 04 (Length: 12 min, uploaded: Dec 03, 2021): Testing of AR in state sequencer
  • F 05 (Length: 09 min, uploaded: Dec 03, 2021): Testing of AR in the Autorecoser test module

Part G: Voltage and Frequency Protection Functions (ANSI 27, ANS59, ANSI81O, 81U)

  • G 01 (Length: 06 min, uploaded: Dec 08, 2021): Ramping test modules and testing the frequency functions
  • G 02 (Length: 05 min, uploaded: Dec 08, 2021): Paulse ramping test module
  • G 03 (Length: 06 min, uploaded: Dec 08, 2021): Continous ramp and step ramp
  • G 04 (Length: 11 min, uploaded: Dec 08, 2021): How to test Over/Under voltage protection functions (59, 27)

Part H: Study and review of different relays

  • H 01 (Length: 10 min, uploaded: Dec 20, 2021): SIPROTEC 7UT6 setting description and configuration
  • H 02 (Length: 14 min, uploaded: Dec 20, 2021): How to test differential function in SIPROTEC 7UT6, No combined characteristic feature, Automate testing by creating SIEMENS 7UT XRIO file
  • H 03 (Length: 18 min, uploaded: Jan 01, 2022): The procedure of testing transformer protection with Quick CMC

Training on Testing and commissioning by Dr. Saeed Roostaee